AMS-1000 Spec
AMS-1000 Boost Controller Specifications

by AMS-1000 Sales email the content item print the content item create pdf file of the content item

Click the link up top to immediately "Purchase Online"

View or upload pictures of the vehicles that run an AMS-1000 in the gallery!

IMPORTANT ANNOUNCEMENT:
Only purchase the AMS-1000 from an authorized dealer -- otherwise there is NO support and NO warranty!


Quick contacts: sales@ams1000.com & support@ams1000.com

Introducing the AMS-500 Two-Stage Boost Controller

AMS 500

Overview
The AMS-500 Boost Controller can control 2-Stages and/or levels of boost. The 2-Stages are controlled by Input1 and Input2. Both of these inputs can be configured using a DIP Switch for either Ground or +12 volt activation. Input1 may be configured to function as a “Launch” stage when used in conjunction with Input2. Input2 offers an adjustable ramp rate as well as boost level settings.

Each stage has a range of adjustment from 0 to 40psi with 1psi resolution and is controlled to within .1psi to target using advanced control algorithms. If a setting greater than 40psi is configured the AMS-500 will default to the maximum 40psi allowed. A setting of 0 PSI will turn either stage off.

An optional Safe Mode is available when using a pressure source other than the manifold pressure. The Safe Mode continually checks for the proper pressure increase and will disable the system and open the decrease solenoid in the event of an error condition.

When in Normal Mode of operation the AMS-500 will keep trying to apply pressure to the waste gateuntil its target is reached.

IMPORTANT—The AMS-500 controls the pressure on the Waste Gate so the actual boost level obtained is a combination of the Waste Gate Spring pressure and pressure applied by the controller. (Just like the AMS-1000)  This controller comes with everything you need to connect it up and use except for an external air source if desired.

The AMS-1000 has reset the standards for boost control!

The AMS-1000 multi-channel Air Management System represents the latest in digital boost control technology. A Motorola 50-Mhz 16-bit processor is used to provide accurate and extremely fast control. A 128x64 pixel graphical LCD is used to provide a live display of data and inputs. GUI (Graphical User Interface) style operating system makes setup and programming more intuitive and user friendly.Data logging is integrated into the AMS-1000 and provides the user with instant feedback on the performance and real time operating parameters. The Data is presented as a Graph with a scrolling capability for detailed data information. If only the main boost channel is used for control of a waste gate the Aux channel MAP Sensor input then can be used to log actual manifold pressure. If both channels are used for control then the logged data will represent the real time pressure applied to each channel during operation.
Support for multiple types and pressure range MAP sensors have been provided so the system can be tailored to an individuals needs. Sensor inputs are continuously monitored and any error conditions are reported to the user.GM 3 bar0 to 30 psi range.
SSI 5 bar 0 to 60 psi range.
SSI 6.5 bar 0 to 99 psi range.

Multiple operating modes are available to the user: Time Based, Shift Based, and GPS (Gear Position Sensor):
Time Based One to six timed stages are available with this mode of operation. Each stage has an adjustable timer to control the duration. The Ramp Rate (rate at which the pressure is applied) is adjustable from 0 to 100 psi per second. A Ramp Rate setting of 0 does not disable the stage. The target psi will instantly rise at the end of any timed stage with a 0 Ramp Rate setting. The target psi can be increased or decreased over time to achieve the desired Boost Profile.Shift Based One to six stages are available and are controlled by a shift-input signal. The Ramp Rate for each stage is programmable as well as the Target psi for each stage (gear position). The Ramp Rate settings perform the same functions as in Time Based mode.
GPS Based One to six stages are available and are controlled by a 0-5 volt analog Input signal. This mode is for newer sport bikes or any vehicle that produces a different voltage for each gear position. A switch that produces a different voltage for each position can be used to select different boost profiles (up to six) on vehicles that do not use a Gear Position Sensor system. The Ramp Rate for each stage is programmable as well as the Target psi for each stage (gear position). The Ramp Rate settings perform the same functions as in Time Based Mode. Data logging is NOT available with this mode of operation.

The controller comes with everything you need to hook it up and start using it except for the external air source, if desired.

Read on!
  • Billet aluminum enclosure and all parts are specified over an extended temperature range.
  • Vibration and weather proof.
  • System software can be erased and reprogrammed by the factory for future software updates.
  • User settings will remain for up to 20 years with no power applied. No back up batteries are needed.
  • Factory default RESET available in the options menu to restore controller to state it was out of the box from the factory.
  • Launch mode programmable to range of selected MAP sensor.
  • Scramble boost to apply an amount of pressure that you program to the gate, thus increasing boost no matter where in the main program you are currently at. Think of it as an emergency boost button (kinda like a shot of nitrous) Remove the signal and it goes back to current target psi. Can be used as a single stage of boost.
  • Reduce boost which works the opposite of scramble. It will remove a programmed amount from the current target psi. If you spin stab a button and it will reduce power instantly.
  • Delay timer for Activation in Shift Based Mode and First stage of Time based mode may be used as a delay timer.
  • Multiple operating modes:
  • Time Based (up to 6 stages) programmable to ONE one-hundredth of a second.
  • Shift Based (up to 6 stages) programmable to ONE one-hundredth of a second.
  • GPS (up to 6 gears), self learning, can be used on anything with a voltage output to indicate gear position -- programmable to ONE one-hundredth of a second.
  • Programmable Ramp Rate to control the rate at which the pressure is applied. 0 to 100 psi range.
  • Dual output channels available or the auxiliary channel may be used for live boost pressure data viewing and data logging. Basically there are 2 controllers in 1 box. You can control multiple waste gates , valves, blow offs on supercharged systems thus giving you boost control.
  • Integrated Dual channel data logger with 35 seconds of record for each channel. Graph view of logged data. Logged data will remain until it is erased by user.
  • Graph view of programmed settings.
  • Display backlight and contrast is user adjustable from the options menu.
  • Help screens and setup wizards to help with setup.
  • Most inputs can be configured for + 12volt or ground activation.
  • All inputs have input protection diodes. All outputs have integrated noise suppression devices to clamp fly back voltage from solenoids.
  • Outputs short circuit protected and over current protected( 7 amp Maximum)
  • Reverse battery protection.
** NOTE Target PSI is the amount applied to the waste-gate and is NOT the actual Manifold Boost Psi! **